Cannot convert between unicode and non-unicode string data types error in SSIS – Nishant Rana’s Weblog
While using the OLE DB Source component in SSIS, on updating its SQL Command we started getting the below error for “Phone” column in our Table.
The fix is to open the Advanced Editor for the OLE DB Source component
Change the Data Type (non-unicode string) for the Phone column inside Output Columns in Input and Output Properties Tab.
Changing the Data Type from Unicode string [DT_WSTR] to string [DT_STR] fixed the issue.
Hope it helps..
Continue Reading Nishant Rana’s Article on their blog